Account Contact
Je winkelwagen
DPD & FedEx – bezorgdatum op de productpagina.
Hulp nodig? DistriNode AI helpt je met alles op onze site.

Glasvezel-simplex-patchkabel InLine LC/APC (8°) naar SC/APC (8°) 9/125 µm OS2, 2 m

Glasvezel-simplex-patchkabel InLine LC/APC (8°) naar SC/APC (8°) 9/125 µm OS2, 2 m
Glasvezel-simplex-patchkabel InLine LC/APC (8°) naar SC/APC (8°) 9/125 µm OS2, 2 m
Glasvezel-simplex-patchkabel InLine LC/APC (8°) naar SC/APC (8°) 9/125 µm OS2, 2 m
Glasvezel-simplex-patchkabel InLine LC/APC (8°) naar SC/APC (8°) 9/125 µm OS2, 2 m
Glasvezel-simplex-patchkabel InLine LC/APC (8°) naar SC/APC (8°) 9/125 µm OS2, 2 m
Glasvezel-simplex-patchkabel InLine LC/APC (8°) naar SC/APC (8°) 9/125 µm OS2, 2 m
9,09 €
PDF
PDF
Voorraad 19 Code 1429519 Model 88402 Garantie 2 jaar

Bezorging & retourneren

Verwachte bezorgdatum donderdag 26 november
Je blijft op de hoogte via ons uitgebreide trackingsysteem
Betaalopties
BetaalkaartVisaMastercardPayPalApple PayGoogle PayBankoverschrijving

Stel een vraag – de AI-assistent antwoordt direct.

Omschrijving

Single-fiber simplex patch cable InLine LC/APC (8°) to SC/APC (8°) 9/125µm OS2, 2 m is a pre-assembled single-mode duplex replacement cable designed for FTTH and point-to-point optical connections. The cable uses OS2 9/125 µm fibre and features an LC/APC connector on one end and an SC/APC connector on the other, both with 8° APC polish for low back-reflection. The armoured 3.0 mm outer sheath and internal stainless steel spiral tube provide mechanical protection suitable for in-home routing between the house transfer point, ONT/OLT and fibre modem.

Advantages

The cable combines a compact LC form factor with the robust SC interface to allow flexible device and patch-panel connections while keeping insertion loss low and return loss high. Its halogen-free outer jacket and reinforced metal tubing increase durability compared with thin factory-supplied jumpers, reducing the risk of breakage during installation or everyday use. The product is delivered with test report data and complies with relevant IEC standards for fibre performance and fire/toxicity behaviour.

Suitable for

  • FTTH installations linking the home entry point to ONT/ONT ports or home routers
  • Patch panel to network equipment connections in premises and small data closets
  • Single-mode optical links requiring APC-terminated connectors to minimise back-reflection
  • Replacement of thin or damaged pre-installed consumer fibre jumpers

Key specifications

  • Fibre type: OS2 single-mode, 9/125 µm
  • Connectors: LC/APC (8°) to SC/APC (8°)
  • Cable outer diameter: approx. 3.0 mm (armoured)
  • Internal reinforcement: stainless steel spiral tube
  • Insertion loss (typical): <0.20 dB; maximum <0.30 dB
  • Return loss: >60 dB (APC)
  • Polish type: APC 8°
  • Operating temperature range: -40 °C to +85 °C
  • Sheath: halogen-free, white
  • Cable length: 2 m

How to use

Connect the LC/APC end to the device or patch panel port sized for LC connectors and the SC/APC end to the corresponding SC port. Ensure both connector ferrules and device ports are clean before mating to avoid performance degradation; use a fibre-cleaning tool or lint-free swabs with appropriate cleaner. Route the cable without sharp bends and avoid compressing the armoured tube; maintain the minimum bend radius recommended for single-mode jumper cables. Verify link quality after installation using the supplied test report or appropriate optical test equipment.

Recommendations

Store and install the cable in a dry environment, avoid exposure to prolonged UV light or chemicals. When replacing existing consumer jumpers, choose this sturdier 3 mm armoured cable to reduce the likelihood of damage during handling. For best optical performance, use APC-terminated connectors throughout the link where optical reflections must be minimised, and perform post-installation insertion loss and return loss checks if network equipment supports them.

How to use

Connect the LC/APC end to the device or patch panel port sized for LC connectors and the SC/APC end to the corresponding SC port. Ensure both connector ferrules and device ports are clean before mating to avoid performance degradation; use a fibre-cleaning tool or lint-free swabs with appropriate cleaner. Route the cable without sharp bends and avoid compressing the armoured tube; maintain the minimum bend radius recommended for single-mode jumper cables. Verify link quality after installation using the supplied test report or appropriate optical test equipment.

Recommendations

Store and install the cable in a dry environment, avoid exposure to prolonged UV light or chemicals. When replacing existing consumer jumpers, choose this sturdier 3 mm armoured cable to reduce the likelihood of damage during handling. For best optical performance, use APC-terminated connectors throughout the link where optical reflections must be minimised, and perform post-installation insertion loss and return loss checks if network equipment supports them.

Belangrijkste kenmerken
  • Halogen free outer Jacket
  • Armoured Cable OD:3.0mm±0.2mm
  • flexible metal tubing one core
  • Fiber: OS2 9/125µm - single Mode
  • I-VH-2E,G.652.D
  • APC 8° Polished
  • IL<0.30dB,RL>60dB
  • IL(typical)<0.20dB
  • with test report
  • Conform IEC 610304-2 IEC60332-3-1 IEC60754-2 IEC 61754-20
  • Operating Temperature: -40 to +85°C
  • Storage Temperature: -40 to +85°C
  • OS2
  • 2 m
  • LC Male
  • SC Male
  • Connector polish type: APC
  • Single-mode
  • White

Specificaties

Specificaties
Aansluiting 1
LC
Aansluiting 2
SC
Afmetingen (B x H x D)
170 x 2000 x 8 mm
Bedrijfstemperatuur (T-T)
-40 - 85 °C
Breedte verpakking
165 mm
Diepte verpakking
170 mm
Full duplex
No
Geslacht aansluiting 1
Mannelijk
Geslacht aansluiting 2
Mannelijk
Gewicht
34 g
Gewicht verpakking
41 g
Hoogte verpakking
80 mm
Kabeldiameter
3 mm
Kabellengte
2 m
Kerndiameter
9 µm
Manteldiameter
125 µm
Opslagtemperatuur (T-T)
-40 - 85 °C
Productkleur
Wit
Structuur vezelmodus
Single-mode
Testprotocol inbegrepen
Ja
Type connectorpolijsting
APC
Type glasvezel
OS2
Verpakkingsvolume
2300 cm³
Prijsverloop van de afgelopen 6 maanden
Glasvezel-simplex-patchkabel InLine LC/APC (8°) naar SC/APC (8°) 9/125 µm OS2, 2 m
Actueel
9,09 €
Laagste 7 d
9,00 €
Hoogste 7 d
9,42 €
Wijziging 24 uur
0,00 €   0%
Wijziging 7 d
-0,34 €   -4%
Wijziging 30 d
0,00 €   0%

Review schrijven

Beoordeling *
Opmerking: HTML wordt niet omgezet!

Meer INLINE producten in deze categorie

12

Populaire producten in deze categorie

7
Verkoper / Vendeur : UAB KUR LT · Laisvės pr. 125A, LT-06118 Vilnius, Litouwen / Lituanie · Ondernemingsnr. / N° d’entreprise 303192950 · Btw-nr. / N° TVA LT100008198612 · Verzending vanuit de EU (Litouwen) / Expédition depuis l’UE (Lituanie)
WhatsApp
Messenger
Hoi, ik ben de AI-assistent van DistriNode. Ik help je graag met het vinden van producten, het vergelijken van opties, het maken van offerte-PDF's of het openen van supportaanvragen.
Alle categorieën